Water Heater Discharge Pipe Size
Boiler prv discharge pipe how to stop odours with hotun.
Water heater discharge pipe size. Scalding water and steam escape the tank through the valve and tube to relieve the pressure. Simultaneously and the outpout from each of the heaters the hot out feeds either different building areas apartments or users case parallel 1 or feeds a manifold that then joins the output from all of the heaters to feed a single hot water line. 5 c the discharge pipe may not be trapped. The discharge piping serving a pressure relief valve temperature relief valve or combination valve shall.
Don t set it next to anything hot or flammable. Install the water heater in an area where it won t be cramped. For unvented hot water heater applications over 15 litres capacity click here. This pipe is responsible for routing hot water released from the tpr to a proper discharge location.
Place a level on the side of the water heater and plumb it with plastic shims. Local building codes vary but most require a catch pan under the water heater with a discharge pipe that ends above the rim of the pan to provide an air gap between the pipe and a pan full of water. We don t know of any specific minimum in the international building code irc or florida building code fbc but the sizing of water distribution pipes is based on a combination of fixture units which is a number assigned to different types of plumbing fixtures according to their likely water usage and the length of piping in the system. Not be directly connected to the drainage system.
5 b the discharge pipe and fittings shall have a diameter not less than the diameter of the relief valve outlet. To buy one of our hotun dry trap tundishes or products please see our trade suppliers list here. Turn the water heater so that access to the burner and controls is unobstructed. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap.
Discharge through an air gap located in the same room as the water heater. The valve should be connected to a discharge pipe also called a drain line that runs down the length of the water heater tank. 8 termination of the tpr drain pipe cannot be more than 6 inches or less than two pipe diameters above the floor ground or waster receptor flood rim level. 5 a the discharge pipe and fittings shall be made of a material acceptable for water distribution piping in accordance with s comm 84 30 4 e 1.
The example shown below with the pipe almost touching the floor will impede the water flow and cause it to splash upwards. For unvented hot water heater applications under 15 litres capacity click here. Parallel water heater hookups which i think you are describing basically are feeding cold water in parallel to multiple water heaters i e.